Abstract

The problem of radiation-produced defects in n-Ge before and after n-> p conversion is discussed in the light of electrical data obtained by means of Hall effect measurements as well as Deep Level Transient Spectroscopy. The picture of the dominant radiation defects in irradiated n-Ge before n-> p conversion appears to be complicated, since they turn out to be neutral in n-type material and unobserved in the electrical measurements. It is argued that radiation-produced acceptors at ~ EC-0.2 eV previously ascribed to vacancy-donor pairs (E-centers) play a minor role in the defect formation processes under irradiation. Acceptor defects at ~ EV+0.1 eV are absolutely dominating in irradiated n-Ge after n-> p conversion. All the radiation defects under consideration were found to be dependent on the chemical group-V impurities. Together with this, they are concluded to be vacancy-related, as evidenced positron annihilation experiments. A detailed consideration of experimental data on irradiated n-Ge shows that the present model of radiation-produced defects adopted in literature should be reconsidered. DOI: 10.21883/FTP.2017.12.45178.8599

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.