Abstract

The BABAR experiment has been using two polycrystalline chemical-vapor-deposition (pCVD) diamonds for radiation monitoring for nearly 2 years. In July 2005, an additional 12 diamond based radiation sensors will be installed inside the BABAR detector. These diamonds will take over the function of 12 silicon PIN-diodes that are currently used in the radiation protection and monitoring system. We describe our highly successful experience with using pCVD diamond radiation sensors in a high energy physics experiment. We also detail our findings of persistent signal currents and magnetically suppressed erratic dark currents in pCVD diamond based radiation sensors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.