https://doi.org/10.1016/j.nima.2005.06.028
Copy DOIPublication Date: Jul 1, 2005 | |
Citations: 22 |
The BABAR experiment has been using two polycrystalline chemical-vapor-deposition (pCVD) diamonds for radiation monitoring for nearly 2 years. In July 2005, an additional 12 diamond based radiation sensors will be installed inside the BABAR detector. These diamonds will take over the function of 12 silicon PIN-diodes that are currently used in the radiation protection and monitoring system. We describe our highly successful experience with using pCVD diamond radiation sensors in a high energy physics experiment. We also detail our findings of persistent signal currents and magnetically suppressed erratic dark currents in pCVD diamond based radiation sensors.
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.