Abstract
Estimates of the radiation absorbed dose in critical device oxide layers due to x‐ray and direct‐write electron beam lithography are developed. Layered structures of photoresist, aluminum, silicon dioxide, and silicon are used for explicit calculations. It is shown that radiation levels in the Megarad range can be expected for both of these advanced lithographic techniques. The consequences of this process‐induced radiation damage are briefly considered.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.