Radiation heat transfer in high porosity open-cell metal foams subjected to cryogenic temperatures has been studied. This study helps designing metal-foam-based devices exposed to radiation of deep space at extremely low temperature. Aluminium and copper foam samples with more than 90% and 95% void volume respectively and pore size in the range of 10–30 PPI have been studied. Suspending the foam samples freely inside a vacuum chamber (at 10−6mbar) and maintaining the chamber wall at liquid nitrogen temperature, the cool down time–temperature profiles has been recorded for nearly 5.5h, wherein different foams reach temperatures in the range of 119–128K. Simultaneously, theoretical model based on lumped-capacity analysis has been developed to simulate the transient behaviour of foam samples. Simple cubic structure foam model has been used to estimate the view factor. The experimental outcome could be predicted by the theoretical model with reasonable accuracy. Additionally, cool-down history of an aluminium foam sample has been compared to a solid body of same weight so as to appreciate their radiative potential at low temperatures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.