Abstract
AbstractUsing the Extense Source Formulation (Irazoqui et al., 1973a), a radiation distribution model for the tubular lamp‐elliptical reflector system was developed for predicting energy density profiles inside the elliptical cavity of the system.It introduces a significant improvement over the linear‐lamp models since it avoids any form of singularities in the prediction of radiation energy density profiles at the focal points of the elliptical reflector. Also, all lamp and reflector dimensions are parameters of the model.Calculated results agree well with published experimental data for a similar lamp reflector set up.One of the most important conclusions is the absence of uniform irradiation from all radial directions at the reactor location.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.