Abstract

Dose rate measurements were performed at 0, 0.5, and 1 m from the external surface of 79 patients corresponding to the most frequent studies: 99mTc-cardiac with reinjection, 99mTc-cardiac single injection, 99mTc-bone scan, 99mTc-lung studies, and cardiac studies using 201Tl. Doses to staff, nearby patients, and the collective effective doses were estimated for the different working shifts and hospital areas. The estimated dose for nurses for 1 y was 518 microSv in the cardiology section and 338 microSv in the short stay section. For patients, the mean dose per stay was calculated to be 8.5 microSv in the cardiology section. The maximum dose that a patient could receive from a radioactive patient is 499 microSv for a double injection cardiac patient study. The maximum collective effective dose for the whole hospital was calculated to be 0.063 person-Sv. The probability of staff receiving doses higher than the limits for a working day is negligible. Maximum doses for staff and patients are far below dose limits for the public and therefore no additional radiological protection is needed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.