Abstract

External beam radiotherapy (EBRT) treatment planning requires a fast and accurate method of calculating the dose delivered by a clinical treatment plan. However, existing methods of calculating dose distributions have limitations. Monte Carlo (MC) methods are accurate but can take too long to be clinically viable. Deterministic approaches are quicker but can be inaccurate under certain conditions, particularly near heterogeneities and air interfaces. Neural networks trained on MC-derived data have the potential to reproduce dose distributions that agree closely with the MC method while being significantly quicker to deploy. In this work we present a framework for training machine learning models capable of directly calculating the dose delivered to a point in three-dimensional (3D) heterogeneous media given only spatially local information. The framework consists of three parts. First, we describe a novel method of randomly generating 3D heterogeneous geometries using simplex noise. Dose distributions for training were obtained by importing these geometries into a MC simulation. The second and third parts of the framework are precalculated data channels, aligned with the patient computed tomography (CT) image, to be used as input to the model. These data channels are a computationally efficient way of encoding the parameters of an incident radiation beam while also allowing the model to learn from data that would otherwise be outside of its receptive field. We demonstrate the viability of the framework by a training small, fully connected neural network model to reproduce dose distributions from megavoltage photon beams. The trained network displayed excellent agreement with MC dose distributions in randomly generated geometries with an average gamma index (3%/3mm) pass rate of 94.7% and an average error of 1.45% of peak dose. Finally, the network was used to calculate the dose in a patient CT image, on which the network was not trained, producing similarly impressive results. A novel method of generating training data for learned radiation dosimetry models has been introduced, along with preprocessing steps that allow even simple models to reproduce accurate dose distributions for EBRT. More importantly, we have demonstrated that a model trained using the proposed framework can generalize from the training data to predicting the therapeutic dose in realistic media.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.