Abstract

The purpose of the this study was to measure the entrance surface air kerma (ESAK) and body organs, and the effective doses in intravenous urography (IVU) X-ray examinations in Sudanese hospitals. Seventy-two patients who underwent IVU multiple radiographs from five hospitals (six rooms) were examined. ESAK was calculated from incident air kerma (Ki) using patient exposure parameters and tube output Y(d). Dose calculations were performed using CALDOSE X 5.1 Monte Carlo-based software. Risk of cancer induction (4–8) and mortality per million (2–4) varied. The gallbladder, colon, stomach, gonads and uterus received organ doses of 5.3, 3.6, 3.2, 0.61, and 0.8mGy, respectively. ESAK values ranged from 6.6 to 15.3mGy (effective doses: 0.70–1.6mSv). Mean ESAK fall slightly above the diagnostic reference level. Several optimization strategies to improve dose performance were discussed. Reducing the number of radiographs and the use of technique charts according to patient sizes and anatomic areas are among the most important dose optimization tools in IVU.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.