Abstract

The cation-exchange Nafion N117 membranes swelling in electrolyte solution were irradiated with γ-rays or electron beams at various doses up to 1500 kGy in the temperature range from room temperature to 343 K to obtain detailed information on the effect of ion-exchange on the radiation deterioration in mechanical properties and ion-exchange capacity. Considerable deterioration in mechanical properties was observed when the Nafion membranes swelling in electrolyte solution were irradiated. A reason is the promotion of degradation with oxygen molecules produced by the irradiation of electrolyte solution. The concentration of electrolyte solution influenced strongly the radiation deterioration in mechanical properties. Keeping the concentration of metal ions to be negligible is important when electrolyzed highly radioactive solution in the light of the durability of polyperfluorosulfonic acid (PFSA) membrane. A sort of cation in electrolyte solution negligibly influenced radiation deterioration in mechanical properties. A sort of anion in electrolyte solution had negligible effect on radiation deterioration in mechanical properties and ion-exchange capacity. The discrepancy in the radiation deterioration in mechanical properties of Nafion membranes swelling in NaCl solution was observed between the specimens irradiated with γ-rays and electron beams. This discrepancy can be explained from the low diffusivity of oxygen from bulk into the membrane.