Abstract
Polystyrene based scintillator SCSN38, wavelength shifter Y7 with polymethylmethacrylate matrix and pure PMMA light guide GS218 have been irradiated in the mixed radiation field of a pool reactor. About 77% of the dose released in SCSN38 was caused by the /spl gamma/-field, 23% by fast neutrons. The total dose ranged from 2 to 105 kGy. The dose measurements were made using alanine dosimeters. Transmission and fluorescence of the samples have been measured before and several times after irradiation. The radiation damage results show no differences to irradiations in pure /spl gamma/-fields with corresponding released doses. >
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.