Abstract

Thermal gravimetric analysis of the samples of VP-1AP anion exchanger in sulfate and nitrate forms was carried out. In the derivatograms of the anion exchanger in the nitrate form there are one endothermic and two exothermic peaks (∼100, 160-180, and 200-220°C). Heating of dry samples of VP-1AP anion exchanger in the nitrate form at 130-230°C induces oxidative degradation of the sorbent matrix with participation of nitrate ions. In the presence of products of anion exchanger degradation and sorbed HNO3 in the anion exchanger phase, the weight loss of the samples abruptly increases at temperatures of approximately 180-190°C. The action of ionizing radiation strongly affects the heat resistance of the anion exchanger. At absorpbed dose of 5 MGy the first exothermic peak is shifted by 15-20°C; in this case, both exothermic peaks coalesce and the oxidation can be considered as single-stage process starting at 110°C.