Abstract
The paper concerns the comparison between reverberation chamber measurements (RC) and anechoic chamber (AC) measurements: in particular, the case of an immunity test is considered. A two-wire transmission line is adopted as a device under test (DUT), and the current induced on the line by the external field is monitored to construct a possible susceptibility profile. Both the averaged current, over the stirrer rotation, and the maximum current are considered to show how robust is the RC measurement against the positioning and the orientation of the DUT inside the chamber. As expected from theory, the maximum value is related to the average one by means of the number of the independent position of the stirrer. Finally, it is highlighted how in RC it is possible to lost some worst case situations, related to a particular incident field polarization and incoming direction, and the underestimation of the induced current depends upon the chosen number of the stirrer positions
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.