Abstract

A technique to measure radiated BPF sound from an automotive turbocharger compressor impeller is proposed in this paper. Where there are high-level background noises in the measurement environment, it is difficult to discriminate the target component from the background. Since the effort of measuring BPF sound was taken in a room with such condition in this study, no discrete BPF peak was initially found on the sound spectrum. Taking its directionality into consideration, a microphone covered with a parabolic cone was selected and using this technique, the discrete peak of BPF was clearly observed. Since the level of measured sound was amplified due to the area-integration effect, correction was needed to obtain the real level. To do so, sound measurements with and without a parabolic cone were conducted for the fixed source and their level differences were used as correction factors. Consideration is given to the sound propagation mechanism utilizing measured BPF as well as the result of a simple model experiment. The present method is generally applicable to sound measurements conducted with a high level of background noise.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.