Abstract

Radially resolved hydrogenic isotope fraction measurement capabilities have been developed for DIII-D using the main-ion charge exchange recombination (MICER) spectroscopy system in preparation for mixed hydrogen and deuterium experiments. Constraints on the hydrogenic ion temperatures and velocities based on measurements of the impurity ion properties are required to accurately fit the spectrum. Corrections for cross sectional distortions, spatial smearing due to the halo, and a neoclassical offset between the impurity and hydrogenic toroidal rotation are applied to the constraints prior to fitting the MICER spectrum. Extensive atomic physics calculations have been performed using the FIDASIM code, which has recently been improved to allow simulations using mixtures of hydrogenic species. These results demonstrate that for the same plasma parameters, the Dα emission is 20%-30% brighter than Hα due to differences in rate coefficients associated with the different ion thermal velocities for the same temperature and therefore must be taken into consideration when calculating absolute densities. However, despite these differences, the absolute error when estimating the hydrogen isotope fraction [nH/(nH + nD)] by using the Hα radiance fraction [LHα/(LHα + LDα)] is typically less than 5% due to the way the fraction is formed, making the radiance fraction a reasonably accurate estimate of the isotope fraction for most cases.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.