Abstract
Strain gage methods are popular in experimental determination of stress intensity factors (SIFs). Radial location of gages with respect to the crack tip plays an important role in accuracy of strain measurements and thus accurate determination of SIFs. The present work proposes a finite element based simple, accurate and consistent method for determination of the limiting value of the radial distance ( r max) of a strain gage. This parameter is in turn useful in deciding the valid strain gage location for accurate measurement of opening mode SIF. The results obtained from the present investigation agree well with the theoretical predictions and could be used for experimental determination of SIFs for both single ended and double ended cracked specimens. The r max values of center cracked and edge cracked plates with different crack length to width ratio are estimated. The results of the present investigation show that the relative size of the crack length and net ligament length strongly influences the r max value and the effect of Poisson’s ratio is marginal on the r max value.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.