Abstract

Experimental measurements of the radial restricted linear energy transfer (LETr) for alpha beams of 18.3 MeV/n in tissue-equivalent gas were presented. The radial dose distribution for the alpha beam was deduced from the restricted LET measurements. A differential W value for the alpha particle in the tissue-equivalent gas was also deduced. The result for the differential W value was 29.0 +/- 0.9 eV/ion pair. The radial dose varied according to an inverse-square function with distance from the track center for radii larger than 0.026 micron. The maximum extension of the track, the penumbra radius, as 2.73 +/- 1.67 microns, which was less than predicted by calculations (7-9 microns).