Abstract
Van Allen Probes A and B, launched more than a year ago (in August 2012), carried 16 p-channel metal-oxide-semiconductor Radiation-sensitive Field Effect Transistors (RadFET)s into an orbit designed by NASA to probe the heart of the trapped-radiation belts. Nearly 350 days of in situ measurements from the Engineering Radiation Monitor (ERM) (1) demonstrated strong variations of dose rates with time, (2) revealed a critical correlation between the ERM RadFET dosimeters and the ERM Faraday cup data on charged particles, and (3) permitted the mapping of the belts by measuring variation with orbit altitude. This paper provides an update on early results given in a NSREC2012 paper along with details and discussion of the RadFET dosimetry data analyzed .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: IEEE Transactions on Nuclear Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.