Abstract

In this study, we investigated the impact of the environmentally friendly R290 refrigerant, which has a higher Coefficient of Performance (COP), on the operating performance of the cooling system, as an alternative to the commonly used R404A refrigerant, which has a negative effect on global warming. The boundary conditions in the refrigeration cycle were designed to be -10°C evaporation and +45°C condensation, and the performance of the system referenced in the TS EN ISO 23953-2 standard was experimentally compared for both refrigerants. The temperature and energy consumption values of the M-packs, whose location and quantity are specified in the relevant standard, have been evaluated in terms of the cooling performance of the cabinet. As a result of the study, the heat removal performance of the system using R290 fluid in the condenser showed better results compared to R404A. According to the relevant standard, the system using R290 is in the C and D classes in the energy consumption evaluation.