Abstract

AbstractA method for estimating free gossypol (FG) has been developed that decreases sample‐determination time from over 2 h to about 25 min per sample. With auto pipetters and bottle‐to dispensers, six sample determinations can be completed in approximately 50 min. The method consisted of adding water and acetone separately to a fixed sample weight, mixing, filtering, diluting with 65% acetone, and reading absorbance on a spectrophotometer. Absorbance was plotted against the official American Oil Chemists’ Society’s FG method for samples that contained FG between 0.02 and 0.9%. Quadratic least squares regression for 31 samples had a correlation coefficient ofr2=0.986 and a standard error of estimated FG of 0.032%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.