Abstract

Particulate emission sampling was conducted at Dofasco’s No. 2 Coke Want Quench Tower in August 1977. The sampling was performed by York Research Corporation using EPA developed quench tower sampling techniques. Particulate emissions averaged 0.245 lb/ton of coal over 17 tests. The mist eliminator in the tower consists of two rows of zig-zag baffles inclined at 20° from the vertical. Particle size data indicated that the majority of the particulate emissions were less than 10 microns in diameter. A mathematical model was used to predict the effect of particle size and gas velocity on collection efficiency. Pressure drop and re-entrainment are two restrictions which are considered in baffle design. Quench towers are the largest contributor to Dofasco’s allowable off-the-property suspended particulate impingement concentration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.