Abstract

Vertical electrical sounding technique (VES) is used as an alternative approach to pumping test for computing the Quaternary aquifer transmissivity in the Khanasser Valley, Northern Syria. The method is inexpensive, easy and gives faster results with higher special resolution than the traditional pumping technique. The hydraulic conductivity values obtained using VES agree with the pumping test results, which in the Khanasser Valley vary between the order of 0.864 and 8.64 m/day (10−5 and 10−4 m/s). The probable location of the Quaternary aquifer in the Khanasser Valley is obtained through the transmissivity map derived from VES. The knowledge of transmissivity is fundamental for modeling and management processes in the Khanasser Valley. Other similar semiarid regions can benefit from the approach successfully applied in the study area.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.