Abstract

A two-story full-scale CLT platform-type building of 4.5 m × 9.1 m in plan, with a height of 5.04 m, was tested under quasi-static monotonic and cyclic loading. The main objectives were to evaluate the global response of the structure, the performance of the shear walls, the behaviour of the connectors (hold-downs and angle brackets) and the frequency response of the structure during the tests. Lateral loads were applied on the storeys inducing torsion to the building. Loading procedure, number and disposition of connectors varied between tests. However, it is important to note that, in order to avoid a possible overlap of effects, the metal connectors hold-downs and angle-brackets only have been placed in CLT shear walls in each loading direction. In terms of performance, longitudinal direction presented a stiffer behaviour when compared to the transverse, where it was possible to verify greater sliding in the longitudinal direction and global rocking in the transverse direction. The results of this experimental campaign will be used for further analytical and numerical analyses, in order to help to implement more detailed seismic analysis, namely pushover, of CLT constructions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.