Abstract

The disruption of the endocrine systems of gastropod molluscs and consequential physiological changes (imposex and intersex) are used as biomarkers for environmental contamination by tributyltin compounds. The first international laboratory performance study on the determination of imposex and intersex in neogastropod molluscs, Nucella lapillus and Littorina littorea has been undertaken by the QUASIMEME (Quality Assurance of Information for Marine Environmental Monitoring in Europe) project. Samples of live gastropods were distributed and participants were asked to record shell height and sex, together with penis length and vas deferens sequence stage (VDS) in Nucella or the intersex stage (IS) and prostate length in Littorina. Calculations were made of vas deferens sequence index (VDSI) and the relative penis size index (RPSI) in Nucella and of intersex stage index (ISI) and the average female prostate length (FPrL) in Littorina. Thirteen (87%) of the 15 participating laboratories returned data. The remaining two laboratories asked to participate in later exercises. For Nucella, seven laboratories reported sex ratios significantly different from the reference laboratory data. Differences in penis length measurements between laboratories were largely random, although there were indications of systematic errors affecting the data from three laboratories. Seven laboratories reported satisfactory data (Z-score magnitude of Z < 2) for VDSI. The inclusion of a high proportion of sub-adults in the Nucella samples may have made separation of the sexes more difficult than in mature adults. The sub-adults will have had smaller pene than mature adults in the same population, and therefore any errors (random or systematic) in the measurement of penis length or observation of reproductive organs would have a potentially greater impact on the final reported values of the summary imposex indices. The Littorina sample did not show a high degree of intersex (ISI = 0.41). The laboratories could determine the sex of Littorina reliably and only one laboratory reported data significantly different from the reference laboratory. All except two laboratories reported satisfactory data for ISI.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.