Abstract
AbstractTo solve the fabrication problems of traditional precast shear walls caused by too many connections joints, a new type of precast shear wall with unconnected vertically distributed reinforcements and concealed bracings is developed in this paper. Four full‐scale shear walls, including one cast‐in‐place specimen and three precast specimens, were tested under low‐cycle lateral loading conditions to evaluate the seismic performance of the new type of precast shear wall. The test results showed that the loading capacity and energy dissipation of the new type of precast shear wall were comparable to those of the cast‐in‐place specimen; however, the failure mode was similar to the damage mechanism of an infilled wall frame, not the traditional bending‐shear mode of shear walls. Then, a new strut‐and‐tie model considering dowel action was proposed for this new type of precast shear wall. Finally, a parametric study was conducted by finite element analysis to determine a reasonable value of the effective strength coefficient for the strut‐and‐tie model. Good agreement was achieved between the test and model results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.