Abstract

A NUMBER of articles1?6 have been written which deal with the optimum response of a relay servo to a step input, with some mention of a ramp input. If optimum response is defined as that response which regains position correspondence in minimum time and without overshoot, then it has been shown that an ideal relay servo with second order motor-load combination may be optimized. The optimized relay servo has one period of acceleration with maximum torque, an instantaneous torque reversal (ideal relay) at an appropriate point, and one period of deceleration with maximum torque. The system attains zero error and zero error-rate simultaneously, the torque is removed, and the system is stationary at zero error. For the second order motor-load, with a maximum torque specification, this represents the fastest possible response. For higher order motor-load units, more switching operations5 are required.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.