Abstract

The new structure of the quasi-distributed fiber-optic temperature sensor is offered, based on recirculation frequency registration a single pulse with its periodic regeneration on different wavelengths and allowing simultaneously to spend measurements to ten points. Fiber-roptic sensor was constructed as a closed optoelectronic contour formed by a source of radiation, an optical fiber delay line, spectral reflective elements, photoreceiver and regeneration block. The sensitive element of this device was the optical fiber. The error of temperature measurements does not exceed 0.2°C at measurement time 1 s, thus the maximum length of the fiber-optic measuring converter reaches 15 km at use multimode gradient optical fiber.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.