Abstract

Quantum dots (QDs) as a biological labeling material for medical applications need to be evaluated for the sensitivity and stability of their fluorescence. Comparison of QD-based immunolabeling and commonly used immunohistochemical staining in detecting the expression of prostate stem cell antigen (PSCA) in bladder tumor tissues revealed that the two methods had similar sensitivity in the differential display of PSCA expression correlated with tumor stage and grade (kappa=0.92, p<0.001). In addition, the intensity of QD fluorescence remained stable for at least 10 days after conjugation to the PSCA protein and nearly 96% of the positive expression in samples lasted for one month.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.