Abstract

<p>Since a multi area system (MAS) is characterized by momentary overshoot, undershoot and intolerable settling time so, neutral copper conductors are replaced by multilayer zigzag graphene nano ribbon (MLGNR) interconnects that are tremendously advantageous to copper interconnects for the future transmission line conductors necessitated for economic and emission dispatch (EED) of electric supply system giving rise to reduced overshoots and settling time and greenhouse effect as well. The recent work includes combinatorial algorithm involving proportional integral and derivative controller and heuristic swarm optimization; we say it as Hybrid- particle swarm optimization (PSO) controller. The modeling of two multi area systems meant for EED is carried out by controlling the conventional proportional integral and derivative (PID) controller regulated and monitored by quantum behaved artificial bee colony (ABC) optimization based PID (QABCOPID) controller in MATLAB/Simulink platform. After the modelling and simulation of QABCOPID controller it is realized that QABCOPID is better as compared to multi span double display (MM), neural network based PID (NNPID), multi objective constriction PSO (MOCPSO) and multi objective PSO (MOPSO). The real power generation fixed by QABCOPID controller is used to estimate the combined cost and emission objectives yielding optimal solution, minimum losses and maximum efficiency of transmission line.</p>

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call