Abstract

BackgroundIn Sweden, human tissue samples obtained from diagnostic and surgical procedures have for decades been routinely stored in a formalin-fixed, paraffin-embedded, form. Through linkage with nationwide registers, these samples are available for molecular studies to identify biomarkers predicting mortality even in slow-progressing prostate cancer. However, tissue fixation causes modifications of nucleic acids, making it challenging to extract high-quality nucleic acids from formalin fixated tissues.MethodsIn this study, the efficiency of five commercial nucleic acid extraction kits was compared on 30 prostate biopsies with normal histology, and the quantity and quality of the products were compared using spectrophotometry and Agilent’s BioAnalyzer. Student’s t-test’s and Bland-Altman analyses were performed in order to investigate differences in nucleic acid quantity and quality between the five kits. The best performing extraction kits were subsequently tested on an additional 84 prostate tumor tissues. A Spearman’s correlation test and linear regression analyses were performed in order to investigate the impact of tissue age and amount of tissue on nucleic acid quantity and quality.ResultsNucleic acids extracted with RNeasy® FFPE and QIAamp® DNA FFPE Tissue kit had the highest quantity and quality, and was used for extraction from 84 tumor tissues. Nucleic acids were successfully extracted from all biopsies, and the amount of tumor (in millimeter) was found to have the strongest association with quantity and quality of nucleic acids.ConclusionsTo conclude, this study shows that the choice of nucleic acid extraction kit affects the quantity and quality of extracted products. Furthermore, we show that extraction of nucleic acids from archival formalin-fixed prostate biopsies is possible, allowing molecular studies to be performed on this valuable sample collection.

Highlights

  • In Sweden, human tissue samples obtained from diagnostic and surgical procedures have for decades been routinely stored in a formalin-fixed, paraffin-embedded, form

  • In order to minimize the risk of variation due to different operators, the same operator performed all extractions with one kit

  • The RNeasy® FFPE kit resulted in consistently higher RNA yields ranging from 8.1 ng/ μl to 20.8 ng/μl compared to the samples extracted with High Pure FFPE kit ranging from 2.2 ng/μl to 11.2 ng/μl (p < 0.001)

Read more

Summary

Introduction

In Sweden, human tissue samples obtained from diagnostic and surgical procedures have for decades been routinely stored in a formalin-fixed, paraffin-embedded, form. Through linkage with nationwide registers, these samples are available for molecular studies to identify biomarkers predicting mortality even in slowprogressing prostate cancer. Even though currently used clinical factors for prostate cancer management In Sweden, virtually all human tissue samples obtained from diagnostic and surgical procedures have for decades been routinely stored in formalin-fixed, paraffin-embedded, (FFPE) form [2]. Through linkage with nationwide registers using the unique national registration number, this vast collection of samples are available for molecular epidemiological studies to identify biomarkers predicting mortality even in slow-progressing prostate cancer

Methods
Results
Discussion
Conclusion