Abstract
The relation of space charge-derived quantities with aging stresses and time is discussed in this paper. Polyethylene-based materials, aged for different times under electrical and/or thermal stress, are subjected to space charge measurements. Quantities are derived, that is, the threshold for space charge accumulation and the apparent, trap-controlled mobility, obtained by the threshold and the depolarisation characteristics, respectively, which show time variations depending on the level of applied stress and aging time, i.e. on the extent of degradation. This indicates that such quantities can be considered as aging markers useful for the diagnosis of bulk degradation in insulation systems aged under electrical field, dc or ac, and temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Dielectrics and Electrical Insulation
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.