Abstract

ABSTRACTThe present case study demonstrates that high-precision dilatometry serves as sensitive tool for quantitatively characterising precipitation processes down to small relative length changes in the range of and covering long time scales exceeding s. For a dilute Al-based Al–Mg–Si alloy, the amount of the metastable coherent -phase and the semicoherent -phase as well as of the stable β-phase could be determined on an absolute scale from in-situ relative length change measurements upon long-time isothermal annealing. The quantitative analysis allows an assessment on the various contributions of the length change, i.e. the volume excess of the precipitates, the volume change of the matrix upon precipitation of solute atoms, and the length change due to the formation of interfaces.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.