Abstract

Silicon carbide mirrors were characterized using several qualitative and quantitative nondestructive ultrasound techniques in order to determine the most efficient method for rapid performance evaluations. Ultrasound testing was performed in immersion using both phased array and single transducer systems in pulse‐echo configuration. C‐scan images of top and bottom surface reflected signal peak amplitudes were used to qualitatively locate and identify homogeneity variations within the mirror materials. Quantitative analysis of normalized amplitude histograms revealed significant differences in homogeneity estimations between phased array and single transducer test methods. Acoustic spectroscopy over the 10–33 MHz regime identified bulk microstructural differences between high and low amplitude regions in the samples. While ultrasound phased array performed well at rapidly locating surface and subsurface heterogeneities, it could not match the resolution and clarity of single transducer C‐scan images or the insight of acoustic spectroscopy analyses.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.