Abstract

Methods Dogs (n=12) underwent coronary occlusion (2 hours), during which microspheres were injected into the left atrium, followed by reperfusion (4 hours). The entire left ventricle was imaged at 1.5T (Siemens) in contiguous short-axis slices with a Modified Look-Locker Inversion-recovery sequence for T1 mapping (Messroghli, JMRI, 2007), and a T2-prepared SSFP sequence for T2 mapping (Giri, JCMR, 2009). Myocardium at risk was defined as regions in the left ventricle which had a T1 or T2 value greater than 2SD from remote. In four dogs, hearts were excised and blood flow (ml/min/g) was determined by microsphere analysis in 16 sectors per short-axis slice for all short-axis slices in the left ventricle. Myocardium at risk was defined as regions in the left ventricle with a blood flow at occlusion less than 2SD from remote. Results Global myocardium at risk, expressed as percent of left ventricular mass (%LVM), showed similar results for T1 mapping compared to T2 mapping (n=12, mean+/SD difference 1.5+/-4.0 %LVM, R2=0.86, p<0.001). On a slice-by-slice basis (n=4 dogs, 34 slices), myocardium at risk was also similar for T1 and T2 mapping (difference 0.4+/-7.6 % of slice, R2=0.96, p<0.001), T1 mapping corresponded to microsphere analysis (mean difference 2.0+/-12.8 % of slice, R2=0.90, p<0.001), and T2 mapping corresponded to microsphere analysis (mean difference 1.6+/-13.8 % of slice, R2=0.86, p<0.001). Figure 1. Conclusions When it comes to determining myocardium at risk after coronary ischemia and reperfusion, clinical non-contrast T1 mapping and T2 mapping sequences yield similar results, and both correspond excellently to microspheres. It appears that the relaxation properties T1 and T2 both change in a way which is consistent with the myocardial edema which occurs following myocardial ischemia/reperfusion.

Highlights

  • Clinical quantitative T1 and T2 mapping sequences are available, but it is unclear which, if either, is more accurate for determining myocardium at risk.Purpose To validate and determine the accuracy for using in vivo T1 mapping or T2 mapping for determining myocardium at risk, compared to blood flow quantification at coronary occlusion by microspheres

  • Global myocardium at risk, expressed as percent of left ventricular mass (%LVM), showed similar results for T1 mapping compared to T2 mapping (n=12, mean+/SD difference 1.5+/-4.0 %LVM, R2=0.86, p

  • On a slice-by-slice basis (n=4 dogs, 34 slices), myocardium at risk was similar for T1 and T2 mapping, T1 mapping corresponded to microsphere analysis, and T2 mapping corresponded to microsphere analysis

Read more

Summary

Introduction

Clinical quantitative T1 and T2 mapping sequences are available, but it is unclear which, if either, is more accurate for determining myocardium at risk. Purpose To validate and determine the accuracy for using in vivo T1 mapping or T2 mapping for determining myocardium at risk, compared to blood flow quantification at coronary occlusion by microspheres

Methods
Results
Conclusions