Abstract

SummaryBackgroundHeart transplantation is the definitive treatment for many cardiovascular diseases. However, no ideal approach is established to evaluate heart grafts and it mostly relies on qualitative interpretation of surgeon based on the organ aspect including anatomy, color and manual palpation. In this study we propose to assess quantitatively the Shear Wave Velocity (SWV) using ultrasound as a biomarker of cardiac viability on a porcine model.MethodsThe SWV was assessed quantitatively using a clinical ultrasound elastography device (Aixplorer, Supersonics Imagine, France) linked to a robotic motorized arm (UR3, Universal Robots, Denmark) and the elastic anisotropy was obtained using a custom ultrasound research system.SWV was evaluated as function of time in two porcine heart model during 20h at controlled temperature (4°C). One control group (N = 8) with the heart removed and arrested by cold cardioplegia and immerged in a preservation solution. One ischemic group (N = 6) with the organ harvested after 30 min of in situ warm ischemia, to mimic a donation after cardiac death. Hearts graft were revived at two preservation times, at 4 h (N = 11) and 20 h (N = 10) and the parameters of the cardiac function evaluated.FindingsOn control hearts, SWV remained unchanged during the 4h of preservation. SWV increased significantly between 4 and 20h. For the ischemic group, SWV was found higher after 4h (3.04 +/- 0.69 vs 1.69+/-0.19 m/s, p = 0.007) and 20h (4.77+/-1.22 m/s vs 3.40+/-0.75 m/s, p = 0.034) of preservation with significant differences. A good correlation between SWV and cardiac function index was found (r2=0.88) and manual palpation score (r2=0.81).InterpretationMyocardial stiffness increase was quantified as a function of preservation time and harvesting conditions. The correlation between SWV and cardiac function index suggests that SWV could be used as a marker of graft viability. This technique may be transposed to clinical transplantation for assessing the graft viability during transplantation process.FundingFRM PME20170637799, Agence Biomédecine AOR Greffe 2017, ANR-18-CE18-0015.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.