Abstract

Schlieren photography has been used to analyse quantitatively the acoustic field of an electromagnetic acoustic transducer (EMAT). By measuring the angle through which the rays are refracted it is possible to compute the refractive index gradient and thus determine both the absolute and complex pressure related structures of the images. Using this method, planar and focused shock transients generated by the EMAT have been evaluated and compared with transducer derived pressure measurements. The peak pressure in the unfocused shock was found to be 3.2 MPa and 4.6 MPa for the Schlieren and piezoelectric transducer measurements respectively. Corresponding values for the focused shock-wave agreed to within experimental error at about 19 MPa.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.