Abstract

The potential risk exposure of people for hydrogen refueling stations is often a critical factor to gain authority approval and public acceptance. Quantitative risk assessment (QRA) is often used to quantify the risk around hydrogen facilities and support the communication with authorities during the permitting process. This paper shows a case study on a gaseous hydrogen refueling station using QRA methodology. Risks to station personnel, to refueling customers and to third parties are evaluated respectively. Both individual risk measure and societal risk measure are used in risk assessment. Results show that the compressor leak is the main contributor to risks of all three parties. Elevating compressors can be considered as an effective mitigation measure to reduce occupational risks while setting enclosure around compressors cannot. Both measures are effective to reduce risks to customers. As for third parties, societal risks can be reduced to ALARP region by either elevating compressors or setting enclosure around compressors. External safety distance of compressors cannot be considerably reduced by elevation of compressors, but can significantly be reduced by setting compressor enclosure. However, safety distances of the station are not very sensitive to both mitigation measures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call