Abstract
A 2D delineation of ultrashallow B-doped layers was performed by means of selective etch combined with transmission electron microscopy imaging. Specifically, the possibility to extract the active dopant distribution from the profile of the etched region was explored. The etch process was simulated in order to obtain the etch profile evolution and reproduce the experimental data. Good agreement between experimental results and simulated profiles was achieved. Therefore, this experimental technique supported by simulation allows quantitative correlation of the etch depth to the active dopant distribution and the expected etch depth to be calculated for a given dopant profile.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.