Abstract

BackgroundLung ultrasound (LUS) may not detect small, dynamic changes in lung volume. Mean greyscale measurement using computer-assisted image analysis (Q-LUSMGV) may improve the precision of these measurements.MethodsPreterm lambs (n = 40) underwent LUS of the dependent or non-dependent lung during static pressure–volume curve mapping. Total and regional lung volumes were determined using the super-syringe technique and electrical impedance tomography. Q-LUSMGV and gold standard measurements of lung volume were compared in 520 images.ResultsDependent Q-LUSMGV moderately correlated with total lung volume (rho = 0.60, 95% CI 0.51–0.67) and fairly with right whole (rho = 0.39, 0.27–0.49), central (rho = 0.38, 0.27–0.48), ventral (rho = 0.41, 0.31–0.51) and dorsal regional lung volumes (rho = 0.32, 0.21–0.43). Non-dependent Q-LUSMGV moderately correlated with total lung volume (rho = 0.57, 0.48–0.65) and fairly with right whole (rho = 0.43, 0.32–0.52), central (rho = 0.46, 0.35–0.55), ventral (rho = 0.36, 0.25–0.47) and dorsal lung volumes (rho = 0.36, 0.25–0.47). All correlation coefficients were statistically significant. Distinct inflation and deflation limbs, and sonographic pulmonary hysteresis occurred in 95% of lambs. The greatest changes in Q-LUSMGV occurred at the opening and closing pressures.ConclusionQ-LUSMGV detected changes in total and regional lung volume and offers objective quantification of LUS images, and may improve bedside discrimination of real-time changes in lung volume.ImpactLung ultrasound (LUS) offers continuous, radiation-free imaging that may play a role in assessing lung recruitment but may not detect small changes in lung volume.Mean greyscale image analysis using computer-assisted quantitative LUS (Q-LUSMGV) moderately correlated with changes in total and regional lung volume.Q-LUSMGV identified opening and closing pressure and pulmonary hysteresis in 95% of lambs.Computer-assisted image analysis may enhance LUS estimation of lung recruitment at the bedside.Future research should focus on improving precision prior to clinical translation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.