Abstract
Only ± 50% of patients with type 1 von Willebrand disease (VWD) have recognized molecular defects and diagnosis still rests on demonstrating low plasma von Willebrand factor (VWF) protein/function. However, no generalized consensus exists regarding the type and number of VWF variables that should be considered for diagnosis. To compare the quantitative impact of four different criteria to diagnose type 1 VWD. We tested four laboratory criteria on 4298 laboratory studies during a 5-year period. The first was the National Heart, Lung, and Blood Institute recommendation, which diagnoses type 1 VWD with plasma VWF antigen (VWF:Ag) and VWF ristocetin cofactor (VWF:RCo) < 30 IU dL(-1) and possible VWD/'low VWF' with values between 30 and 50 IU dL(-1) . Second, diagnosis was established when two of three variables, VWF:Ag, VWF:RCo, VWF collagen binding assay (VWF:CB), were ≤ 2.5th percentile. Diagnostic criterion for possible VWD/'low VWF' using percentiles was also described. The third criterion (European Group on von Willebrand Disease, EUVWD), uses a plasma level of VWF:RCo (or VWF:CB) ≤ 40 IU dL(-1) for diagnosis. Finally, the Zimmerman Program for the Molecular and Clinical Biology of VWD (ZPMCBVWD) diagnoses VWD if VWF:Ag or VWF:RCo are ≤ 40 IU dL(-1) . The three assays had high correlation and excellent agreement at levels < 120 IU dL(-1) . The National Heart, Lung, and Blood Institute recommendation was followed to diagnose 122 (2.8%) patients with type 1 VWD and 704 (16.4%) with possible VWD/'low VWF.' Using percentiles, the diagnosis of type 1 VWD increased to 280 (6.5%) patients; 169 (3.9%) patients had possible VWD and 180 (4.2%) patients had 'low VWF.' Diagnoses using EUVWD and ZPMCBVWD criteria increased to 339 (7.9%) and 357 (8.3%) patients, respectively. Identical data, analyzed using different criteria, led to almost three-fold difference (2.8-8.3%) in diagnostic rate. This increase is mostly explained by increasing the cut-off values of VWF measurements from < 30 to ≈ 40 IU dL(-1) . Further refinement of the laboratory diagnosis of type 1 VWD is a priority.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.