Abstract

Quantitative hydroxyl concentration time-series measurements have been obtained by picosecond time-resolved laser-induced fluorescence in a series of methane-air and hydrogen-argon-air nonpremixed flames. The recovery of a quantitative time series is complicated by the need to account for fluctuations in the fluorescence lifetime. We have recently developed instrumentation that enables the simultaneous measurement of fluorescence signal and lifetime. The present research represents the first application of this technique to turbulent flames. The correction for hydroxyl lifetime fluctuations is shown to be significant for mean concentrations and thus probability density functions but negligible for power spectral densities (PSD's). The hydroxyl PSD's were found to vary slightly with radial and axial location in the flames and to vary significantly with Reynolds number. However, the PSD's in the H(2)-Ar-air flames are nearly identical to those in the CH(4)-air flames.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.