Abstract
A convenient and accurate quantitative analytical method for the commercial dye products G acid, and Gama acid, has been established by ion-pair reversed-phase high-performance liquid chromatography. Good resolution among G acid, Schaeffer acid, R acid, Gama acid and amino-G acid was achieved. Appropriate selection of UV detection wavelength, 230 nm, has resulted in linear absorption responses over a wide concentration range, 0–8 μg. The application of the method to a study of the rate of ammonolysis of G acid to amino-G acid is described.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.