Abstract
Peripheral arterial disease (PAD) is a chronic occlusive disease that restricts blood flow in the lower limbs, causing partial or complete blockages of the blood flow. While digital subtraction angiography (DSA) has traditionally been the preferred method for assessing blood flow in the lower limbs, advancements in wide beam Computed Tomography (CT), allowing successive acquisition at high frame rate, might enable hemodynamic measurements. To quantify the arterial blood flow in stenotic below-the-knee (BTK) arteries. To this end, we propose a novel method for contrast bolus tracking and assessment of quantitative hemodynamic parameters in stenotic arteries using4D-CT. Fifty patients with suspected PAD underwent 4D-CT angiography in addition to the clinical run-off computed tomography angiography (CTA). From these dynamic acquisitions, the BTK arteries were segmented and the region of maximum blood flow was extracted. Time attenuation curves (TAC) were estimated using 2D spatio-temporal B-spline regression, enforcing both spatial and temporal smoothness. From these curves, quantitative hemodynamic parameters, describing the shape of the propagating contrast bolus were automatically extracted. We evaluated the robustness of the proposed TAC fitting method with respect to interphase delay and imaging noise and compared it to commonly used approaches. Finally, to illustrate the potential value of 4D-CT, we assessed the correlation between the obtained hemodynamic parameters and the presence ofPAD. 280 out of 292 arteries were successfully segmented, with failures mainly due to a delayed contrast arrival. The proposed method led to physiologically plausible hemodynamic parameters and was significantly more robust compared to 1D temporal regression. A significant correlation between the presence of proximal stenoses and several hemodynamic parameters was found. The proposed method based on spatio-temporal bolus tracking was shown to lead to stable and physiologically plausible estimation of quantitative hemodynamic parameters, even in the case of stenotic arteries. These parameters may provide valuable information in the evaluation of PAD and contribute to itsdiagnosis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.