Abstract

To use quantitative fundus autofluorescence (qAF) to analyze different stages of non-neovascular age-related macular degeneration (AMD). In this cohort study, 38 pseudophakic patients and 36 age-matched controls participated. We performed near-infrared, spectral-domain optical coherence tomography and qAF imaging on 31 pseudophakic eyes and controls of participants older than 60 years with non-neovascular AMD phenotypes using the Spectralis HRA + OCT (Heidelberg Engineering, Heidelberg, Germany). The patients included in this study had a mean age of 83.9 years, and 35.7% patients were men. Mean qAF was higher in control participants than in all patients with AMD (P < .001). According to non-neovascular AMD phenotype, mean qAF levels were significantly lower in eyes with subretinal drusenoid deposits than in control eyes (P < .05). The lowest mean qAF was in patients with geographic atrophy. Quantitative fundus autofluorescence of non-neovascular AMD decreases from normal to early to late AMD, suggesting that loss of lipofuscin fluorophores, not increase, signifies AMD progression. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:S34-S42.].

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call