Abstract
We have developed a random walk theory to relate observable fluorescent intensities on tissue surfaces to the presence of several embedded fluorescent masses. This work is an extension of analysis previously carried out for an isolated fluorescent site. Results depend on the optical properties of tissue at the excitation and emission wavelengths, as well as on the location of fluorescent targets and positions of source and detector. Measurements on tissue-like phantoms were performed to test the theory. Analysis of fluorescent signals, performed in accordance with the theory, yields accurate information about the location of the targets. Prospects of a noninvasive quantitative fluorescent imaging system, to diagnose and monitor salivary glands disease, is presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Journal of Selected Topics in Quantum Electronics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.