Abstract

Transbronchial dye marking is a preoperative localization technique aiding pulmonary resection. Post-marking computed tomography (CT) is performed to confirm the locations of the actual markings. This study aimed to evaluate the CT images of dye markings that present as ground-glass opacities (GGO), using quantitative feature analysis. Thin-slice (1 mm) CT images of the dye markings and true ground glass nodule (GGN) lesions were obtained for quantitative analysis with gray-level co-occurrence matrix (GLCM) features. The quantification features including correlation, auto correlation, contrast, energy, entropy, and homogeneity were evaluated. Statistical analysis with boxplot was performed. GLCM features of multi-detector computed tomography (MDCT) images of the dye markings (n=13) and true GGN lesions (n=13) differed significantly in contrast, energy, entropy, auto correlation, and homogeneity. Cone beam computed tomographic (CBCT) image features of another group of dye markings (n=15) also showed a different distribution of feature values, than those of the MDCT images. Quantitative analysis of the dye marking images revealed a discriminative variance, compared with those of the true GGN lesions. Furthermore, the image textures of dye markings on MDCT and CBCT also presented with obvious discrepancies.

Full Text
Published version (Free)