Abstract

This paper investigates the use of acoustic emission (AE) to identify tensile cracks and shear movements in concrete structures. The analysis of AE signals detected during a concrete beam investigation mainly focused on the relationship between signal parameters namely rise time, amplitude, duration and counts. This method allowed crack classification and shear movements to be identified. A laboratory experiment test was completed on a reinforced concrete beam (150 x 250 x 1900 mm). During testing AE data was captured and analysed post-test. Results from the most severely damaged zone, based on visual inspection, was analysed. The results indicated that tensile cracks developed though out the area of analysis, as confirmed by visual observation and relatively little shear movement occurred as would be expected in a reinforced beam.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.