An optical properties extraction algorithm is developed based on enhanced Huygens-Fresnel light propagation theorem, to extract the scattering coefficient of a specific region in an optical coherence tomography (OCT) image. The aim is to quantitatively analyze the OCT images. The algorithm is evaluated using a set of phantoms with different concentrations of scatterers, designed based on Mie theory. The algorithm is then used to analyze basal cell carcinoma and healthy eyelid tissues, demonstrating distinguishable differences in the scattering coefficient between these tissues. In this study, we have taken advantage of the simplification introduced by the utilization of a dynamic focus OCT system. This eliminates the need to deconvolve the reflectivity profile with the confocal gate profile, as the sensitivity of the OCT system is constant throughout the axial range.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.