Active thermography is an infrared-based technique for nondestructive testing of materials. It often uses advanced evaluation techniques based on temperature spatial and temporal changes. Results of active thermography are contrast differences, which indicate possible defects in an inspected material. These differences cannot be quantified by temperature. This contribution is focused on the active thermography results' evaluation parameters and the contrast-to-noise ratio method, which can be used for quantitative evaluation of the results. Different result interpretation procedures are introduced. The influence of a selection method for indication and reference regions and the effect of image scaling on inspection results are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.