Abstract
Summary In this chapter, an isocratic reverse phase HPLC determination of mimosine was developed and validated in an anti-psoriatic topically applied formulation “Lajjalu”. The chromatography was performed on a C18 column with water-orthophosphoric acid (98.8:0.2, υ/υ) as a mobile phase with a pH of 3.0 at a flow rate of 1.0 mL min−1. Detection was performed at 284 nm, and a sharp peak was obtained for mimosine at a retention time of 2.62 ± 0.01 min. Linear regression analysis data for the calibration plot showed a good linear relationship between response curve and concentration in the range of 0.050–5000 ng mL−1 and the regression coefficient was 0.9998 with the linear regression equation y = 4766.8x−17726. The detection (LOD) and quantification (LOQ) limits were 10.3 and 35.6 ng mL−1, respectively. The wide linearity range, sensitivity, accuracy, short retention time, and simple mobile phase imply the method is suitable for routine quantification of mimosine with high precision and accuracy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.