Abstract

The first wall of the fusion device TEXTOR at the Forschungszentrum Julich has been coated in situ with an amorphous hydrogen rich carbon/boron film (a-C/B:H) which reduces plasma impurities caused by the plasma surface interaction. The results of the coating process of the 35 m2 large inner wall surface have been controlled by a recently developed modification of the quantitative electron probe microanalysis, which has been applied to 12 samples from specified positions inside the tokamak. The quantification itself is based on a Monte Carlo simulation of electron trajectories providing very accurate results for X-ray intensities emitted by elements present in the electron bombarded sample. The Monte Carlo results are used in the present work to calibrate the measured X-ray intensities emitted by boron and carbon from the a-C/B:H layers deposited on pure silicon substrates. As a result the total deposited mass of the layer per area unit as well as the composition of the layers (except hydrogen) could be determined very accurately. The relative errors were less than 7%. The limit of detectability were found to be in the range of one monolayer for boron as well as for carbon.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.